3. the boiler room is a class d engineering building with a height (at least 7 m to 10 m). there is no room above the boiler. it is a separate engineering building. if it is placed in the factory area, be sure to be a non-pressure boiling water boiler or a steam boiler not more than 2 t/h.
4. The boiler room must be equipped with a monitoring room and a chemical laboratory (which can be shared with the monitoring room), high-precision digital thermostat supply soft water treatment system, sub-cylinder, gas pressure regulating station, timely and regular sewage treatment expansion tank, desuperheating pool, exhaust system, pipe trench, equipment handling and maintenance gate, etc.
5. the boiler make-up water tank must be placed in a low position, the air duct of the smoke exhaust system must be insulated and insulated, and the explosion relief sheet, condensate exhaust pipe and smoke and dust economizer must be set to facilitate energy saving.
6. the boiler feed water pump is a multi-stage centrifugal pump with high pulling force, which can be reserved manually or operated in full-automatic frequency conversion mode.
7. No machinery and equipment can be placed on the front, back, left, and right of the boiler, high-precision digital temperature controller manufacturers water purification equipment is farther away from the boiler and is more strongly set in a separate room. 8. The boiler flue is reinforced and each boiler is equipped with its own independent flue.
9. the refrigeration room is divided and the large water tank is canceled. the beam bottom is laid. the pipeline adopts the female control to divide the water. the gate valve adopts the electric butterfly valve, which can reduce the friction resistance of the system software, occupy less total area and facilitate the actual operation. 10. The closed-circuit cooling tower design offers greater flexibility; as the server cooling capacity increases, it can delay the simultaneous startup of two servers, resulting in significant cost savings and energy efficiency. In particular, pay attention to the fact that the water supply pipe exiting the cooling tower sump is a non-pressurized line (32°C), and it must slope downward only—never upward.
